Chapter 3 Technical Information
RFU63x RFID Write/Read Device (UHF)
10 © SICK AG · Germany · All rights reserved · Subject to change without notice 8014335/YUO7/2016-04-04
Mounting
3.2 Optional mounting accessories
3.2.1 Installing wall mounting plate (no. 2060912) on the RFU630
Procedure for attachment on the RFU630:
1. Either cut two M6 threads or install two bore holes with 6.5 mm through the assem-
bly base provided by the customer with a spacing of 227 mm.
2. For the time being,fasten two supplied M6 x 16 mm screws in the assembly base such
that the thread protrudes at least 8 mm up to the base of the screw head.
3. Install the mounting plate on the rear side of the RFU630 using the three supplied
M5 x 12 mm screws.
4. Attach the RFU630 together with the mounting plate onto the two protruding M6
screws and tighten them.
20
24
240
239
227
136.8
16
4
M6
Mounting plate 1 (for mounting to walls)
All dimensions in mm
30
227
198
61.2
0
7
218.6
32.5
53.5
240
136.8
16.4
5
7.5
M5
(12.5)
Ø
12
Ø
6.6
Ø 6
.6
Ø 5.5
M5
M6
RFU630-131xx
Hexagon screw
10 mm width
across flat
3 mm width
across flat
10 mm width across flat
Hexagon socket
3 mm width
across flat