Chapter 3 Technical Information
RFU63x RFID Write/Read Device (UHF)
16 © SICK AG · Germany · All rights reserved · Subject to change without notice 8014335/YUO7/2016-04-04
Mounting
3.4 Mounting optionals UHF antennas
3.4.1 RFA630-000/-001 antenna
Health hazard due to high-frequency electromagnetic radiation!
The RFA630-000 antenna (region: Europe) is designed for operation in accordance with
ETSI EN 302208. During operation, the human exposure regulations covered by EN 50364
must be observed.
In order to limit human exposure to electromagnetic fields, suitable safety distances
must be maintained during both short-term and long-term work in the radiation range
antenna(e).
Minimum distances to be maintained between the antenna and the human body during
long-term transmission:
30 cm with a max. radiation power of the antenna of 2 W ERP as per ETSI,
15 cm with a reduced radiation power of 1 W ERP,
10 cm with a radiation power of 0.5 W ERP.
The RFA630-001 antenna (region: USA/Canada/Mexico) satisfies the limit values of the
FCC for exposure to radiation in an uncontrolled environment.
During operation, a safety distance of at least 20 cm must be maintained between the
antenna and the human body.
113.1 (4.45)
48.4
(1.91)
6.5
(0.26)
44.4
(1.75)
113.1 (4.45)
12.9
(0.51)
238.6 (9.39)
238.6 (9.39)
X
X
64.3
(2.53)
15.1
(0.59)
28
(1.10)
164.4 (6.47)
59.5
(2.34)
32.5
(1.28)
40
(1.57)
Ø 14.5
(0.57)
23.5
(0.93)
8.2
(0.32)
80 (3.15)
136.8 (5.39)
3
1
2
Alle Angaben in mm (inch)
All dimensions in mm (inch)
1
Sacklochgewinde M5, 8 tief
Tapped blind hole M5, 8 (0.31) deep
2
Sacklochgewinde M6, 11 tief
Tapped blind hole M6, 11 (0.43) deep
3
Elektrischer Anschluss (TNC, reverse)
Electrical connection (TNC, reverse)