Name Value Meaning
SxDO1 0 Pin 4 of Port x is low (SIO mode, Digital Output)
1 Pin 4 of Port x is high (SIO mode, Digital Output)
In IO-Link mode each IO-Link port will always have one status byte of input data (“Port
Qualifier Information”, PQI). It contains the following data:
Bit Description
Bit 7 Device Process Data validity (PQ)
0 = Invalid IO Process Data from Device
1 = Valid IO Process Data from Device
Bit 6 Port/Device error indication (DevErr)
0 = No error/warning occurred
1 = Error/warning assigned to Device or Port occurred
Bit 5 Device communication (DevCom)
0 = No Device available
1 = Device detected and is in PREOPERATE or OPERATE state
Bit 4 Port activation (PortActive)
0 = Port de-activated via port function
1 = Port activated
Bit 3 Substitute Device detection (SubstDev)
0 = No substitute Device detected (identical SerialNumber)
1 = Substitute Device detected (different SerialNumber)
Bit 2 New parameter (NewPar)
0 = No update of Device parameter detected
1 = Update of Device parameter detected: Master performed
a Data Storage upload and a new IOLD Backup object
(0xB904) is available
Logic Editor Process Data (Slot 1, subslot 2)
For the Logic Editor (Slot 1, subslot 2) the following process data submodules are avail‐
able:
7
SIG200 CONFIGURATION
24
O P E R A T I N G I N S T R U C T I O N | Sensor Integration Gateway - SIG200 8017853/2019-06-06 | SICK
Subject to change without notice