7.1.2.2.1.20 IO Provider Status Output
This bit states the validity of the output data source.
Characteristic Value
PROFINET access SIG200 IO-Link Master (Slot 2, Subslot 1)
Index 0xB200/0xB201/0xB202/0xB203, Byte 6, Bit 0: IOPSO
Encoding 0 Output Data Source invalid
1 Output Data Source valid
7.1.2.2.1.21 Port configured by webserver
Port configured by PDCT allows you to read out if the port is set to be configured by the
PDCT (see "Port configuration mode", page 32).
It is only possible to access this setting through the PLC interface.
Characteristic Value
PROFINET access SIG200 IO-Link Master (Slot 1, Subslot 1)
Index 0xB200/0xB201/0xB202/0xB203, Byte 6, Bit 2: PDCT
Encoding 0 Port configured by PLC
1 Port configured by webserver
7.1.2.2.1.22 IOL_CALL
IOL_CALL is a PROFINET protocol add-on allowing to access IO-Link On-request data
(ISDU parameters). It is specified in PROFIBUS Nutzerorganisation (PNO) document “IO-
Link Integration – Edition 2, Guideline for PROFINET” Version 1.0 – June 2017 (Order
No.: 2.832).
IOL_CALL can be located in a PLC as a function block (FB). The FB will need at least the
following parameters:
Parameter Definition
ID Address of any of the available IO-Link Device submodules or IO-
Link Master submodule
CAP The Client Access Point (CAP) represents the PROFINET record
index providing the “tunnel” to the IO-Link system. The value of
this index is 0xB400.
Port IO-Link port number the function shall be performed at (0…3).
Note that this value is not relevant when accessing IOL_CALL
through one of the IO-Link Device submodules since one submod‐
ule is fixed to one port.
RD/WR Indicates whether the On-request data shall be read (RD) or writ‐
ten (WR).
IOL_Index Index of the On-request data or Port Function Command Code
IOL_Subindex Subindex of the On-request data or Port Function Command Code
IOL_Data On-request data to be written to or to be read from IO-Link Device
7.2 Operation via Webserver
The SIG200 can be accessed through its integrated webserver. In order to do so you
need to identify the IP address of the SIG200. Please contact the relevant network
administrator or use SOPAS Engineering Tool to read out the current IP address. Alter‐
natively SIG200 also offers its IP address via UPNP (Universal Plug & Play).
The default IP address of SIG200 is: 192.168.0.1
The following web browser software is supported:
SIG200 CONFIGURATION 7
8017853/2019-06-06 | SICK O P E R A T I N G I N S T R U C T I O N | Sensor Integration Gateway - SIG200