EasyManua.ls Logo

SICK SIG200

SICK SIG200
102 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9
C/DI/DO LED for pin 4
ß
Mounting hole for front mounting
à
Mounting hole for side mounting
á
Removable user defined port labels
â
USB Port (M8) for configuration with SOPAS ET
LEDs on the fieldbus module
SF
BF
SIG200
POWER CONFIG
1
2
3
LINK
ACT2
LINK
ACT1
P2
P1
Table 1: LED status indicators
LED Indication Meaning
Power green Power on
Power off
BF (Bus fault) dark PROFINET connection ok
red Device offline from PROFINET
red blinking PROFINET communication start up or
invalid configuration
SF (System fault) dark Device ok
green blinking Find Me
red blinking System fault of the device
LINK ACT 1 (Link / Activity 1) dark No network connection on port 1
green Network connection on port 1
LINK ACT 2 (Link / Activity 2) dark No network connection on port 2
green Network connection on port 2
IO-Link Port LEDs (Port S1-S4)
/DO
DI
SIG200
S1
8
9
Legend LED Indication Meaning
8
DI: LED for pin 2 amber Additional DI on pin 2
off No additional DI on
pin 2
9
C/DI/DO LED for pin 4 green Pin 4 - IO-Link commu‐
nication active
green blinking Pin 4 - no IO-Link com‐
munication active
PRODUCT DESCRIPTION 3
8017853/2019-06-06 | SICK O P E R A T I N G I N S T R U C T I O N | Sensor Integration Gateway - SIG200