The Profinet output block allows the injection of process data from the PLC to the logic
which appear as inputs in the workspace.
Outputs
Digital:
Pin 4 can be configured as “Digital outputs” to be addressed by the logic.
NOTE
It is not possible to connect a digital output on pin 2.
Rest:
Through the “Rest Out” block, data from the logic can be sent via REST interface to an
upper system (e. g. HTTP Client).
Profinet:
It is possible to inject process data from the logic editor to the PLC by using the Profinet
Input block.
Logics:
Table 19: Logic blocks
Description Addition of the two input values.
Number of inputs 2
Input data type Integer
Input description num1: first input value
num2: second input value
Number of outputs 1
Output data type Output 1 (“+“): Identical to input data type
Output description result: result after addition of the two input val‐
ues
Settings no settings available
8 DEVICE FUNCTIONS
84
O P E R A T I N G I N S T R U C T I O N | Sensor Integration Gateway - SIG200 8017853/2019-06-06 | SICK