Table 24: Thruth
table
Inp
ut A
Inp
ut B
Out‐
put
1 1 0
1 0 0
0 1 0
0 0 1
Description Combine the input signals with a logical NOR.
Number of inputs 4
Input data type 1-bit (future extension: or n-bit)
Input description levelA: first input
levelB: second input
levelC: third input
levelD: fourth input
Maximum 4 inputs can be linked together. If
you want to link more signals, you can work
with several NOR blocks.
Number of outputs 1
Output data type Identical to input data type
Output description level: the output depends on the various
inputs. For more information see truth table
Settings No settings available
XNOR
Table 25: Thruth
table
Inp
ut A
Inp
ut B
Out‐
put
1 1 1
1 0 0
0 1 0
0 0 1
Description Combine the input signals with a logical
XNOR.
Number of inputs 2
Input data type 1-bit (future extension: or n-bit)
Input description levelA: first input
levelB: second input
levelC: third input
levelD: fourth input
Maximum 4 inputs can be linked together. If
you want to link more signals, you can work
with several XNOR blocks.
Number of outputs 1
Output data type Identical to input data type
Output description level: the output depends on the various
inputs. For more information see truth table
Settings No settings available
NOTE
Please be aware that the Integer values have a value range from 0....65.535. There is
no overflow or underflow indication.
NOTE
The logic editor does only support integers (e. g. 2) and no decimal numbers (e. g.
2,345). In case, the calculated result would be a decimal number, the logic editor will
round up or down.
DEVICE FUNCTIONS 8
8017853/2019-06-06 | SICK O P E R A T I N G I N S T R U C T I O N | Sensor Integration Gateway - SIG200
93
Subject to change without notice