Technical specifications
Minimum Typical Maximum
Operational data
Connection Cable gland (PG 13.5)
Core cross-section 0.2 mm
2
1.5 mm
2
Cable length for cross-section
1)
– 0.25 mm
2
– 0.75 mm
2
– 1.5 mm
2
14 m
42 m
83 m
Ambient operating temperature –25 °C +55 °C
Storage temperature –25 °C +70 °C
Air humidity (non-dewing) 15 % 95 %
Dimensions see Dimensional drawings
Vibration resistance 5 g, 10 ... 55 Hz according to EN 60068-2-6
Shock resistance 10 g, 16 ms according to EN 60068-2-29
Environmental data
Housing Aluminium alloy ALSI12(CU)
Front screen Polycarbonate (scratch-resistant coating)
Circuit boards Glassfibre reinforced epoxy resin
Packaging Corrugated cardboard
1)
When using copper cables ([ = 0.018 U mm