9 Maintenance
This SICK sensor is maintenance-free.
We do, however, recommend that the following activities are undertaken regularly:
Clean the optical interfaces and housing
Check the fittings and plug connectors
Cleaning
NOTICE
Equipment damage due to improper cleaning.
Improper cleaning may result in equipment damage.
Only use recommended cleaning agents and tools.
Never use sharp objects for cleaning.
b
Clean the optical surfaces at regular intervals and, in the event of contamina‐
tion, with a lint-free lens cloth (part number 4003353) and plastic cleaner (part
number 5600006). The cleaning interval essentially depends on the ambient
conditions.
No modifications may be made to devices.
Subject to change without notice. Specified product properties and technical data are
not written guarantees.
10 Technical data
10.1 Technical specifications
The “Technical Data” section contains only an extract of the technical data of the sensor.
The complete technical data can be found on the homepage www.sick.com under the part number of the sensor.
Features
Table 27: Technical data
WI130T Standard type (1x Out) Advanced type (2x Out)
Adjusted sensor head W130 product family
Supply voltage DC 12...24V ±10%
Power consumption ≤45mA / 24V
Response time 60μs/500μs/2ms (fast/standard/far)
Digital output NPN / PNP open collector
Charging current: ≤100mA, residual voltage: ≤1.8V
Display 7-segment display
Time delay ON / OFF delay 0 ... 9s
Switch-on/off delay 1ms ... 9s
Analog output 4 ... 20mA
Input/output entry External entry
(Single Value Teach-in, input synchroni‐
zation, counter reset)
External entry
(Single Value Teach-in, input synchroniza‐
tion, counter reset)
Output setting
(2x Out output + alarm output)
OPERATING INSTRUCTIONS
60
O P E R A T I N G I N S T R U C T I O N S | Evaluation unit WI130 8020148.1HRJ/2023-02-08 | SICK
Subject to change without notice
en

Table of Contents