9. If the measured value is equal or exceeds the maximum value in the table 1 keep the elevator out
of service since the gearbox needs to be replaced.
10. If the measured value is in the range of the warning distance, but sll below the limit value, the
elevator can be put back into service. In this case it is recommended to increase the frequency of
inspecon.
11. It is recommended to double check the backlash on the output sha according to the procedure
described at paragraph 2.
Table 1
Model Rao
Warning Distance
measured on the
ywheel
Limit measured
on the
ywheel
MR12/C
2/43, 2/53 12 – 16 mm ≥ 17 mm
1/43, 1/45, 1/52 24 – 33 mm ≥ 34 mm
Machine can sll be in
service but plan its
replacement and reduce
the inspecon interval
Machine cannot be
kept in service,
replace it immediately