AC MUM0040 rev. 11 - 14 -
MR12 - MR12C
5°c
40°c
OK
9. NOTES FOR INSTALLATION
WARNING
The locaon in which the winch is installed must have the
following characteriscs:
It must be dry and not dusty: this is essenal to prevent
electrochemical corrosion of mechanical parts and a high
concentraon of water in the lubricang oil. (clean the
machine room before installing the machine).
The room must be venlated: the room must have
adequate openings or condions that allow air circulaon
which dissipates the heat from the motor and the
reducon unit.
The room temperature must be between 5 °C and 40 °C. .
For other temperatures, contact SICOR.
The customer must make sure that the electrical system where the winch will be installed has suitably
gauged cables, is correctly earthed and adequate power is installed.