SIDESHIFT INSTALLATION GUIDE V2.7
12
ELECTRICAL COMPONENTS
Battery Requirements
The batteries supplying the thruster must be cranking type (NOT deep
cycle) capable of supplying the required minimum CCA (Cold Crank Amps),
outlined in the table below. Insufficient battery capacity will lead to poor
performance and possible damage to the thruster motor.
ST/SS Model
Qty
Voltage
Min. Total CCA (A)
230
1x12v
12
850
340 & 230-Dual
2x12v
12 V
1700
240 & 350
2x12v
24 V
850 at 24v
Warning: It is essential that the cold cranking ampere (CCA)
requirements are met as outlined in the table above.
Ensure batteries are load tested and properly charged at all
times to avoid performance problems and thruster motor
damage due to low voltage
Batteries must be installed as close to the motor controller as possible for optimum
performance. In ventilated areas, you can install either AGM or sealed lead acid
starting-type batteries.
BATTERY CAPACITY AND AGE
Under normal circumstances with new and fully charged batteries, you can expect
around 50 thruster cycles before the battery must be recharged.
It is advisable to recharge batteries after each use if possible, to extend the life of
the battery.
As batteries age and with repeated charge cycles, the battery slowly loses its ability
to hold a charge. The deeper the discharge before recharging, the shorter the life of
the battery. Over time it will be able to supply fewer thruster cycles before it
requires recharging and eventually will lack the capacity to allow proper thruster
performance.
Capacity reduces to the point that performance is poor or few thrust cycles are
available before recharging, and the batteries must be replaced.