EasyManua.ls Logo

Siemens 4/8 F-DI DC24V PROFIsafe User Manual

Siemens 4/8 F-DI DC24V PROFIsafe
228 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
SIMATIC Distributed I/O System Fail-Safe Engineering ET 200S Distributed I/O System - Fail-Safe Modules
_
_____________
_
_____________
_
_____________
_
_____________
_
_____________
_
_____________
_
_____________
_
_____________
_
_____________
_
_____________
_
_____________
_
_____________
Preface
Product Overview
1
Configuring
2
Address Assignment and
Installation
3
Wiring and Fitting Modules
4
Diagnostics
5
General Technical
Specifications
6
Fail-Safe Modules
7
Diagnostic Data of Fail-Safe
Modules
A
Dimension drawings
B
Accessories and Order
Numbers
C
Response times
D
Connecting Loads
E
SIMATIC
Distributed I/O System Fail-Safe
Engineering
ET 200S Distributed I/O System -
Fail-Safe Modules
Installation and Operating Manual
08/2008
A5E00103686-07

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Siemens 4/8 F-DI DC24V PROFIsafe and is the answer not in the manual?

Siemens 4/8 F-DI DC24V PROFIsafe Specifications

General IconGeneral
BrandSiemens
Model4/8 F-DI DC24V PROFIsafe
CategoryControl Unit
LanguageEnglish

Summary

Preface

Important Note for Maintaining Operational Safety of Your System

Emphasizes adherence to operational safety requirements and product monitoring for safe systems.

Product Overview

1.3 Using ET 200S Fail-Safe Modules

Details possible uses of ET 200S with fail-safe modules in F-systems.

1.4 Guide for Commissioning of ET 200S with Fail-Safe Modules

Lists steps for commissioning ET 200S distributed I/O systems with fail-safe modules.

Configuring

2.1 Configuring ET 200S with Fail-Safe Modules

Presents example configurations for ET 200S with standard and fail-safe modules.

2.2 Assigning Modules of an ET 200S

Details module assignments for fail-safe power and electronic modules to terminal modules.

2.3 Maximum Number of Connectable Modules/Maximum Configuration

Covers limitations and maximum configuration for ET 200S modules.

2.4 Configuration and Parameter Assignment

Explains the procedure for configuring and assigning parameters for ET 200S fail-safe modules.

Address Assignment and Installation

3.1 Address assignments in the F-CPU

Shows address ranges occupied by fail-safe modules in the F-CPU.

3.2 Assignment of the PROFIsafe address

Details how to set and assign the PROFIsafe address on each fail-safe module.

Wiring and Fitting Modules

Diagnostics

General Technical Specifications

Fail-Safe Modules

7.2 PM-E F pm DC24V PROFIsafe Power Module

Details properties, wiring, parameters, and diagnostics of the PM-E F pm DC24V PROFIsafe.

7.3 PM-E F pp DC24V PROFIsafe power module

Covers properties, wiring, parameters, and diagnostics of the PM-E F pp DC24V PROFIsafe.

7.4 PM-D F DC24V PROFIsafe Power Module

Details properties, wiring, parameters, and diagnostics of the PM-D F DC24V PROFIsafe.

7.5 4/8 F-DI DC24V PROFIsafe Digital Electronic Module

Describes properties, applications, parameters, and diagnostics of the 4/8 F-DI DC24V PROFIsafe module.

7.6 EM 4 F-DI/3 F-DO DC24V PROFIsafe digital electronic module

Covers properties, applications, parameters, and diagnostics of the EM 4 F-DI/3 F-DO DC24V PROFIsafe module.

7.7 4 F-DO DC24V/2A PROFIsafe digital electronic module

Details properties, wiring, parameters, and diagnostics of the 4 F-DO DC24V/2A PROFIsafe module.

7.8 1 F-RO DC24V/AC24..230V/5A Digital Electronic Module

Covers properties, wiring, parameters, and diagnostics of the 1 F-RO DC24V/AC24..230V/5A module.