Parameter List  09.02 
5-24  Siemens AG    6SE7087-6AK85-1AA0 
  Rectifier/Regenerating Unit    Operating Instructions 
PNU 
 
*
 
: Conf. 
    Par. 
OP1S parameter name 
 
Description 
Value range  
[phys. unit] 
Selection text 
Display 
Indices 
Factory- 
setting 
See 
Modify 
(access / 
status) 
P607 
* 
Trg Bit Warning 
Destination of the status bit 'Warning' (status word 1, bit 7) 
 
Note: 
For issuing the message via a terminal the active status (bit has H-level) is 
inverted (broken wire proof). 
 
Parameter values, indices: as P600 
 
PNU=25FHex; Type=L2; Scaling: 1Hex 
=
∧
 1 
0 to 4212  2 
(0) 
2/    BR 
2/    BR 
P608 
* 
Trg Bit Deviat. 
Destination wiring of the status bit "U
d 
 set  = U
d
 act“ (status word 1, bit 8) - 
cf. P517 
 
Parameter values, indices: as P600 
 
PNU=260Hex; Type=L2; Scaling: 1Hex 
=
∧
 1 
0 to 4212  2 
0 
3/    BR 
3/    BR 
P610 
* 
Trg Regen Ready 
Destination wiring of the status bit "Regenerating ready" (status word 1, 
Bit 10) 
 
Parameter values, indices: as P600 
 
PNU=260Hex; Type=L2; Scaling: 1Hex 
=
∧
 1 
0 to 4212  2 
0 
3/    BR 
3/    BR 
P611 
* 
Trg Low Voltage 
Destination of the status bit 'Undervoltage' (status word 1, bit 11) 
 
Note: 
For issuing the message via a terminal the active status (bit has H-level) is 
inverted (broken wire proof). 
 
Parameter values, indices: as P600 
 
PNU=263Hex; Type=L2; Scaling: 1Hex 
=
∧
 1 
0 to 4212  2 
0 
3/    BR 
3/    BR 
P612 
* 
Trg Bit Contact 
Destination of the status bit 'Energize main contactor' (status word 1, bit 12) 
H level: energize contactor! 
 
Important: Relay X9-4/5, whose function cannot be programmed, is 
provided for controlling the main contactor. 
 
Parameter values, indices: as P600 
 
PNU=264Hex; Type=L2; Scaling: 1Hex 
=
∧
 1 
0 to 4212  2 
0 
3/    BR 
3/    BR 
P613 
* 
Trg DC V reduced 
Destination wiring for the status bit "U
d
 reduced“ 
(status word 1, bit 13) 
 
Parameter values, indices: as P600 
 
PNU=265Hex; Type=L2; Scaling: 1Hex 
=
∧
 1 
0 to 4212  2 
0 
3/    ABR 
3/    ABR 
P614 
* 
** 
Trg Motor/Regen 
Destination wiring for the status bit "Regenerative/motoring mode" (status 
word 1, bit 14) 
 
Parameter values, Indices: as P600 
 
PNU=266Hex; Type=L2; Scaling: 1Hex 
=
∧
 1 
0 to 4212  2 
0 
3/    BR 
3/    BR 