18
Fault Type 1: V
XDCR
> -17.5 Vdc or V
XDCR
< -26 Vdc
Possible causes:
Faulty power source
Faulty field wiring
Faulty Proximitor Sensor
Measure
V
PS
:
V
PS
> -17.5 Vdc or V
PS
< -26 Vdc?
Yes
Faulty Power
Supply
No
V
PS