EasyManua.ls Logo

Siemens CP 1242-7 GPRS V2 - Page 114

Siemens CP 1242-7 GPRS V2
132 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical specifications
7.1 Technical specifications of the CP
CP 1242-7 GPRS V2
114 Operating Instructions, 10/2016, C79000-G8976-C311-02
Technical specifications
Current consumption (typical)
From 24 VDC (external)
75 mA
From the S7-1200 backplane
bus
150 mA
Effective power loss (typical)
From 24 VDC (external)
1.8 W
From the S7-1200 backplane
bus
0.5 W
Permitted ambient conditions
Ambient temperature During operation with the rack
installed horizontally (DIN rail
horizontal)
-20 °C ... +70 °C
During operation with the rack
installed vertically (DIN rail ver-
tical)
-20 °C ... +60 °C
During storage
-40 °C ... +70 °C
During transportation
-40 °C ... +70 °C
Relative humidity
During operation
≤ 95 % at 25 °C, without condensation
Design, dimensions and weight
Module format
Compact module S7-1200, single width
Degree of protection
IP20
Weight
Net weight
Weight including packaging
133 g
170 g
Dimensions (W x H x D)
30 x 100 x 75 mm
Installation options
35 mm DIN rail
Switch panel
You will find additional functions and performance data in the section Application and
functions (Page 9).