LEDs and connectors
2.2 LEDs
CP 1243-7 LTE
30 Operating Instructions, 04/2017, C79000-G8976-C381-03
DIAG
(red / green)
NETWORK
(red / green)
CONNECT
(green)
SIGNAL
QUALITY
(yellow /
green)
VPN
(green)
Meaning
Connection to communications partners
green
- - Connection established to at least one part-
ner, CPU in RUN
green
- - Connection established to at least one part-
ner, CPU in STOP
flashing
green
- - No partner reachable, CPU in RUN
flashing
green
- - No partner reachable, CPU in STOP
flashing
green
- - Telecontrol configuration exists, partner not
reachable, CPU in RUN mode
flashing
green
- - Telecontrol configuration exists, partner not
reachable, CPU in STOP mode
Quality of the mobile wireless connection
- - -
- Good network (-73 ... -51 dBm)
- - -
- Medium strength network (-89 ... -74 dBm)
- - -
- Weak network (-109 ... -90 dBm)
- - -
- No network (≤ -110 dBm)
flashing red
- -
- Missing external power supply
VPN connections
-
- -
VPN connection established
-
- -
No VPN connection established
- - - -
No VPN connection configured on the CP
Loading firmware