11 Technical Specifications
B3L54
CP 343-1 Lean for Industrial Ethernet / Manual Part B3L
Release 03/2007
C79000-G8976-C198-04
11 Technical Specifications
Transmission rate 10 Mbps and 100 Mbps
Interfaces
Connection to Ethernet 2 x RJ45 jack
Power supply DC +24 V (permitted range: +20.4 V through +28.8
V)
Current consumption
S from backplane bus
S from external 24 V DC
200 mA maximum
TP: approx. 0.2 A maximum
Power loss approx. 5.8 W
Permitted ambient conditions
S Operating temperature
S Transportation/storage
temperature
S Relative humidity max.
S Altitude
0 °C to +60 °C
40 °C to +70 °C
95% at +25 °C
up to 2000 m above sea level
Design
S Module format
S Dimensions (W x H x D) in mm
S Weight approx.
Compact module S7-300; single width
40 x 125 x 120
220 g
Table 11-1 Description of the Approvals
cULus
UL 508
CSA C22.2 No. 142
cULus for hazardous locations UL 1604, UL 2279PT.15
CL. 1, Div. 2 GP.A.B.C.D T..
CL. 1, Zone 2, GP. IIC, T..
CL. 1, Zone 2, AEx nC IIC T..
FM FM 3611
CL. 1, Div. 2 GP.A.B.C.D T..
CL. 1, Zone 2, GP.IIC. T..
Ta:..
CTICK AS/NZS 2064 (Class A).
CE EN 6100062, EN 6100064 (replaces EN
500812)
ATEX Zone 2 EN6007915
II 3 G EEx nA II T..
KEMA 03 ATEX 1228 X
Temperature code “T..” and maximum ambient temperature “Ta:..” as listed on the type plate