HART add-on module
15
10. Device-Specific Commands
Command Number and Data in Command Data in reply
Function
141 Write Integer8 Byte 0 CANAPP.ID Byte 0 Integer value
Byte 1 Attribute.ID
Byte 2 Attribute Qual
Byte 3 Reserved (0x00)
Byte 4-5 Index (2 bytes)
Byte 6 Integer8
142 Write Integer16 Byte 0 CANAPP.ID Byte 0-1 Integer value
Byte 1 Attribute.ID
Byte 2 Attribute Qual
Byte 3 Reserved (0x00)
Byte 4-5 Index (2 bytes)
Byte 6-7 Integer16
143 Write Integer32 Byte 0 CANAPP.ID Byte 0-3 Integer value
Byte 1 Attribute.ID
Byte 2 Attribute Qual
Byte 3 Reserved (0x00)
Byte 4-5 Index (2 bytes)
Byte 6-9 Integer32
144 Write Unsigned8 Byte 0 CANAPP.ID Byte 0 One byte
Byte 1 Attribute.ID
Byte 2 Attribute Qual
Byte 3 Reserved (0x00)
Byte 4-5 Index (2 bytes)
Byte 6 Unsigned 8
145 Write Unsigned16 Byte 0 CANAPP.ID Byte 0-1 Two bytes
Byte 1 Attribute.ID
Byte 2 Attribute Qual
Byte 3 Reserved (0x00)
Byte 4-5 Index (2 bytes)
Bytes 6-7 Unsign16
146 Write Unsigned32 Byte 0 CANAPP.ID Byte 0-3 Four bytes
Byte 1 Attribute.ID
Byte 2 Attribute Qual
Byte 3 Reserved (0x00)
Byte 4-5 Index (2 bytes)
Byte 6-9 Unsign32
147 Write VisibleString Byte 0 CANAPP.ID Byte 0 Length of Message
Byte 1 Attribute.ID Byte 1-x User message
Byte 2 Attribute Qual <32 bytes
Byte 3 Reserved (0x00).
Byte 4-5 Index (2 bytes)
Byte 6-x VisibleString
148 Write OctetString Byte 0 CANAPP.ID Byte 0 Length of Message
Byte 1 Attribute.ID Byte 1-x User message
Byte 2 Attribute Qual <32 bytes
Byte 3 Reserved (0x00)
Byte 4-5 Index (2 bytes)
Byte 6-x OctetString
150 Request Set mode Byte 0 Bit0: SaveMode on(1)off(0) As in command
Bit1: ServiceMode on(1)
off(0) - Bit0 is least sign.
Bit of Byte 0
154 Req/rel UserLock Byte 0 Request = 1, Release = 0 As in command
160 Action Byte 0 CANAPP.ID As in command
Byte 1 Attribute.ID
Byte 2 Attribute Qualifier
170 Set Unit code Byte 0 Variable As in command
0=PV, 1=SV,
2=TV, 3=QV,
4= Totalizer 1
5= Totalizer 2
Byte 1 Unit code
Byte 2 Reserved (0x00)