Faults RemedyCauses
Pressure monitor triggers
alarm.
(gear units with water oilcooler
or air oilcooler)
Oil pressure < 0.5 bar. Oil level at room temperature.
Check and, if necessary, top up oil.
Check and, if necessary, clean oil
filter.
Contact Customer Service.
Check that oil pump is functioning
correctly.
Repair or replace oil pump.
Fault in oilsupply system. Consult operating instructions for
oilsupply system.
Indicator on double
changeover filter triggers
alarm.
Double changeover filter clogged. Change double changeover filter
over as instructed in separate
operating instructions, clean
clogged filter element.
Increased operating
temperature.
Oil level in housing too high.
Oil too old.
Oil badly contaminated.
Defective oilsupply system or
cooling coil.
Gear unit with fan: Suction opening
in air guide cover and/or gearunit
housing badly contaminated.
Check oil level and, if necessary,
adjust.
Check date of last oil change and,
if necessary, change oil.
See section 10.
Change oil. See section 10.
Check the oilsupply system or
cooling coil, replace any defective
parts. Consult operating instructions
for oilsupply system.
Clean air guide cover and gearunit
housing.
Temperature at backstop too
high.
Locking function fails.
Damage to backstop. Contact Customer Service.
Check backstop and,
if necessary, replace.
Main drive motor does not
start.
Wrong direction of rotation of motor.
Incorrect installation and/or defect
of cage with sprags of backstop.
Overrunning clutch blocked.
Incorrect installation and/or defect
of cage with grippers of
overrunning clutch.
Change polarity of motor.
Contact Customer Service.
Install cage of the backstop turned
by 180° and/or replace.
Contact Customer Service.
Install a new overrunning clutch.
Contact Customer Service.
Install cage of overrunning clutch
turned by 180° and/or replace.