Communication blocks
2-14 Function Blocks - FM 458-1 DP
Edition 12.2004
YTS Detailed status display; for additional values at YTS,
refer to: D7-SYS Online Help "Help events".
(Press the F1 button in the CFC and call the topic
"Help on events" uncer "CFC for D7-SYS".)
(Default: 0)
Computation time [µs] FM458-1 DP 23,6
Can be inserted online No
Can be configured in Alarm tasks
Executed in Initialization mode
Normal mode
Special features The DPPEV may only be configured in an
alarm task for which the following alarm
cause is configured in HW-Config
Process alarm 1 (OB40)
If this is not the case, DPPEV signals an
appropriate communications error and stops
processing.
A new alarm of the same time is only again
detected after the alarm task has been
completed.
Configuring data