Communication blocks
2-36 Function Blocks - FM 458-1 DP
Edition 12.2004
2.4.3 CBRFAW Receiving warnings from a COMBOARD
CBRFAW
EXM448 module name, connector
GV CTS CW W
COMBOARD alarms 96 - 81
QTS BO
Module status
YTS W
Status, COMBOARD alarm
channel
The block can only be configured on a FM458 module.
This block receives warnings A81 to A96 of a COMBOARD
(communications submodule of SIMOVERT MASTER DRIVES, e.g.
CBP2 for PROFIBUS DP).
Input CTS of the CBRFAW function block is used to define from which
COMBOARD the warnings are to be received.
Function block CBRFAW may only be configured on a FM458 module
of each COMBOARD. It is configured on the FM458 module, on which
a @FMPAR function block was also configured for the appropriate
COMBOARD.
Initialization inputs:
CTS Configured name of the EXM448/EXM448-2 module and connector X01 or X02, separated by
".".
(Default: - )
Outputs:
CW Outputs COMBOARD warnings A81 to A96
(Default: 0)
QTS Block status:
QTS=1: Block is being processed and is operating error-free.
QTS=0: Block is shut down due to a fault with error output at YTS.
(Default: 0)
YTS Status of the COMBOARD warning channel:
YTS=0: OK condition
For additional values, refer to: D7-SYS online help "Help on events". (press the F1 key in the
CFC and call-up the topic "Help on events" under "CFC for SIMADYN D".)
(Default: 0)