SIMOLINK drive coupling
Function Blocks - FM 458-1 DP 5-17
Edition 12.2004
5.7 SLSVAV SIMOLINK send and receive block for one slave
Hardware addresse SLB
addresse of the slave
Number of send channels
Number of receive channels
setpoint at channel 0
setpoint at channel 1
setpoint at channel 2
setpoint at channel 3
setpoint at channel 4
setpoint at channel 5
setpoint at channel 6
setpoint at channel 7
GV
I
I
I
DI
DI
DI
DI
DI
DI
DI
DI
TAD
A
SL
NSV
NAV
XS0
XS1
XS2
XS3
XS4
XS5
XS6
XS7
SLSVAV
YA0
YA1
YA2
YA3
YA4
YA5
YA6
YA7
SEQ
YF
QF
DI
DI
DI
DI
DI
DI
DI
DI
I
I
BO
A
ctual value from slave 0
A
ctual value from slave 1
A
ctual value from slave 2
A
ctual value from slave 3
A
ctual value from slave 4
A
ctual value from slave 5
A
ctual value from slave 6
A
ctual value from slave 7
Sequence number
Block error status
Group error bit
A maximum of
8 setpoints and
8 actual values
can be transfered to and from one slave. The number of addressed
channels for the setpoints and the actual values is configured at the
inputs.
1. The SLSVAV send and receive block executes the following steps
while the system is being initialized:
Checks the task assignment
Initializes the task-list of the SLB module corresponding to the
data configured at the inputs
2. In the normal system mode ("RUN" mode), the SLSVAV send and
receive block executes the following:
Checks that the inputs are within the permissible value range
Enters the setpoints to be sent into the write buffer of the SLB
module
Reads-out the actual values to be received from the receive
buffer of the SLB module