SIMOLINK drive coupling
5-18 Function Blocks - FM 458-1 DP
Edition 12.2004
TAD
Hardware address SLB (name of the SLB module), which can be
configured in HWConfig
ASL
Address of the slave for dataexchange,
value range 1 . . . 200
(initialization connection)
(default: 1)
NSV
Number of channels for the setpoint to be sent,
value range 0. . . 8
(initialization connection)
(default: 0)
NAV
Number of channels for the actual values to be received,
value range 0 . . . 8
(initialization connection)
(default: 0)
XS0
to
XS7
Setpoint XS for channel 0 to 7,
A maximum of 8 setpoints can be sent.
(default: 0)
YS0
to
YS7
Actual values YS from channel 0 to 7,
A maximum of 8 actual values can be received.
(default: 0)
SEQ
Sequence number
Number of the blocks in the SIMOLINK block sequence
This value provides information as to whether the block was
correctly initialized.
(default: 0)
YF
Error status of the block
YF=0 no error, YF > 0
(default: 0)
QF
Group error bit
QF=0 no error, QF=1 for error (if YF0)
(default: 0)
Computation time [µs] FM458 / PM6 34,7
Can be inserted online no
Can be configured in Interrupt tasks
Cyclic tasks
Executed in Initialization mode
Normal mode
Special features -
I/O