LOGO! Manual
A5E00067781 01
42
3.6.3 Entering a Program
Let’s enter the program now (from the output to the input).
Initially, LOGO! displays the output:
LOGO!’s first output
Q1
The Q of Q1 is underlined. This underlining is the cursor.
The cursor indicates your current position in the program.
You can move the cursor by pressing the , , and
keys. Now press the key . The cursor moves to the left.
The cursor indicates your position in
the program.
Q1
At this point, enter only the first block (the OR block). Press
OK to switch to input mode.
The cursor appears in the form of a
solid block: you can select a connector
or block.
Q1
Co
The cursor no longer appears in the form of an underline;
instead it appears as a solid block that flashes on and off.
At the same time, LOGO! offers you the first list for selec-
tion.
Select the BF list (by pressing until BF appears) and
press OK. LOGO! then displays the first block in the list of
basic functions (BF):
Pro
g
rammin
g
LOGO!

Table of Contents