Do you have a question about the Siemens LOGO! 24RC and is the answer not in the manual?
Power Supply | 24 V DC |
---|---|
Inputs | 8 digital inputs |
Outputs | 4 relay outputs |
Program Memory | 400 function blocks |
Weight | Approx. 250 g |
Protection Class | IP20 |
Dimensions | 72 x 90 x 55 mm |
Mounting Type | DIN rail mounting |
Operating Temperature | 55 °C |
Storage Temperature | -40 to 70 °C |
Defines LOGO! as a universal logic module and lists its integrated components and functions.
Describes diverse applications in domestic, installation, and industrial engineering tasks.
Details the different LOGO! models based on voltage, inputs/outputs, and dimensions.
Illustrates the physical structure and components of LOGO! standard and bus variants.
Provides crucial safety and installation guidelines for wiring LOGO! devices correctly.
Explains the process of mounting and dismounting LOGO! units onto a DIN rail.
Details connection procedures for power supply, inputs, and outputs of LOGO! devices.
Describes how LOGO! behaves upon power-up based on program presence and module status.
Explains how inputs and outputs are identified and connected on LOGO!.
Defines blocks as functions and explains the role of block numbers in program structure.
Guides users on translating conventional circuit diagrams into LOGO! programs using blocks.
Outlines four fundamental rules for efficient and correct LOGO! programming and operation.
Details the steps to switch to programming mode and enter a basic program.
Defines constants, inputs, analog inputs, ASi inputs, and outputs used in LOGO!.
Presents basic Boolean logic functions like AND, OR, NAND, NOR, XOR, NOT with representations.
Provides an overview of special functions, their inputs, and background information.
Explains the On Delay function, its inputs, timing, and operational behavior.
Describes the Off Delay function, its parameters, timing diagram, and function.
Details the Latching Relay function, its set/reset inputs, and switching behavior.
Guides users on entering parameterization mode for adjusting block parameters.
Details the steps to navigate and select a specific parameter for adjustment.
Explains how to modify parameter values, similar to programming mode input.
Introduces LOGO!Soft Comfort, its features like offline generation and simulation.
Explains how to establish a connection between LOGO! and a PC for program transfer.
Details requirements, previous solutions, and LOGO! implementation for stairwell lighting.
Covers demands, previous solutions, and LOGO! based control for automatic doors.
Outlines demands, previous solutions, and LOGO! implementation for ventilation systems.
Lists general technical data including dimensions, weight, and environmental conditions.
Provides detailed technical specifications for LOGO! 230 variants.
Details technical specifications for LOGO! 24 Basic variants.