EasyManua.ls Logo

Siemens MOBILETT XP Hybrid - User Manual

Siemens MOBILETT XP Hybrid
109 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
SP
Instructions for use
MOBILETT XP / XP ECO / XP Hybrid
The New Dimension in Mobile X-ray Imaging

Table of Contents

Other manuals for Siemens MOBILETT XP Hybrid

Questions and Answers

  • G
    gvargasAug 4, 2025
    How to troubleshoot initialization errors in Siemens Industrial Equipment?
    • R
      Rachel WashingtonAug 4, 2025
      If you're experiencing initialization errors with your Siemens Industrial Equipment, begin by verifying the power supply. Ensure the power socket is functional and that the equipment is receiving the correct voltage (e.g., 220V AC). Check the power cable and plug, including the cable winch and line filter. For hybrid models, confirm the operating mode switch SW2 is correctly positioned. Examine the main switch SW1 and relay K22. Inspect fuses F7 and F8 on board D927, and for hybrid/digital models, check fuses F1 and F2 on the battery charger D982. Also, verify the input voltage of power supplies U1, U2, U3 and U4, and check fuse F1 of power supplies U1 and U2. Finally, check the cable connections between power supplies U2 and D927, D927 and D916, and U2 and D916.

Summary

Safety Information

General Safety Information

Covers important safety guidelines, warnings, and general notes for safe operation.

Personal Protection Measures

Details safety precautions for operators and patients regarding mechanical hazards and radiation.

Equipment-Related Safety Measures

Outlines safety requirements for installation, repairs, accessories, transport, and disposal.

Operation Guide

Quick Operational Guides

Provides condensed guides for operating the MOBILETT XP and XP Hybrid models.

Exposure Procedures

Details steps for preparing, adjusting, and releasing X-ray exposures.

System Messages

Radiation Calculation

Dose Area Product (DAP)

Explains the concept, formula, and calculation of DAP.

Exposure Point System

Functional and Safety Checks

Daily Checks

Lists routine daily checks to ensure system readiness and safety.

Cleaning and Disinfecting

Dosimetry

Exposure Tables

Provides tables with standard exposure values for various body parts and sensitivities.

Siemens MOBILETT XP Hybrid Specifications

General IconGeneral
TypeMobile X-ray system
kV Range40 - 125 kV
mAs Range0.1 - 320 mAs
X-ray Tube Focal Spot0.6 / 1.2 mm
Power Supply230 V, 50/60 Hz
X-ray TubeRotating Anode X-ray Tube
Detector Size35 x 43 cm (optional)
Image DisplayIntegrated monitor
ApplicationsGeneral Radiography
Maximum Heat Capacity300 kHU
Image IntensifierNot applicable (digital system)
Digital ImagingYes