8-9
Manual OP5, OP15
( ) J31069-D0840-U001-A2-7618
The data record numbers for the source data record and the destination data
record must be entered in the transfer screen.
The PLC data record is always ”0” for both directions of transfer.
The OP data record must always be specified as a number > 0.
Example of entering source and destination:
OP PLC Transfer
Source Destina-
tion
Description
11 0 Source data record 11 is an existing data record on the OP and
is to become the active data record on the PLC (destination).
PLC OP Transfer
Source Destina-
tion
Description
0 22 The source data record is the active data record on the PLC
which is to appear on the OP (destination) after the transfer
under data record number 22.
If data record number 22 already exists, it can be overwritten
or not if requested.
OP  OP Transfer (i.e., copying)
Source Destina-
tion
Description
33 44 Source data record 33 is an already existing data record on the
OP which is to be copied as data record 44.
If data record number 44 already exists on the OP, it can be
overwritten or not if requested.
Note
Symbolic value entries in the input fields source and destination:
The data record numbers from data records already stored on the OP can be
taken from a data record selection list.
”PLC” stands for data record 0 in the selection list.