Administration
A31003-O1010-M100-9-76A9, 05/05/2008
3-22 HiPath 8000 - OpenStage Family, Administration Manual
administration.fm
IP Network Parameters
Data required
Trap sending enabled: Enables or disables the sending of a TRAP message to the SNMP
manager.
Value range: "Yes", "No".
Default: "No".
Trap destination: IP address or hostname of the SNMP manager that receives traps.
Trap destination port: Port on which the SNMP manager is receiving TRAP messages.
Default: 162.
Trap community: SNMP community string for the SNMP manager receiving TRAP mes-
sages.
Default: "snmp".
Queries allowed: Enables or disables queries from the SNMP manager.
Query password: Password for the execution of a query by the SNMP manager.
Diagnostic sending enabled: Enables or disables the sending of diagnostic data to the
SNMP manager.
Value range: "Yes", "No".
Default: "No".
Diagnostic destination: IP address or hostname of the SNMP manager receiving diag-
nostic data.
Diagnostic destination port: Port on which the SNMP manager is receiving diagnostic
data.
Diagnostic community: SNMP community string for the SNMP manager receiving diag-
nostic data.
QoS traps to QCU: Enables or disables the sending of TRAP messages to the QCU serv-
er.
Value range: "Yes", "No".
Default: "No".
QCU address: IP address of the QCU server.
QCU port: Port on which the QCU server is listening for messages.
Default: 12010.
QCU community: QCU community string.
Default: "QOSCD".
QoS to generic destination / QoS to generic device: Enables or disables the sending of
QoS traps to a generic destination.
Value range: "Yes", "No".
Default: "No".