EasyManua.ls Logo

Siemens RDF600KN User Manual

Siemens RDF600KN
18 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
A6V11425204_en--_d
2020-02-21
Smart Infrastructure
RDF600KN RDF600KN/VB RDF600KN/S
Semi flush-mount
communicating room
thermostats
RDF600KN
RDF600KN/VB
RDF600KN/S
For 2-pipe, 2-pipe with electric heater, and 4-pipe fan coil units
For use with compressors in DX type equipment
· KNX bus communications (S-mode and LTE mode)
· Backlit display
· 2P / PI / P control
· Outputs for on/off or 3-position control
· Outputs for 3-speed or 1-speed fan
· 2 multifunctional inputs for keycard contact, external sensor, etc.
· Operating modes: Comfort, Economy and Protection
· Automatic or manual fan speed control
· Automatic or manual heating/cooling changeover
· Minimum and maximum limitation of room temperature setpoint
· Control depending on the room or the return air temperature
· Adjustable commissioning and control parameters
· Commissioning with Synco ACS, ETS or via local HMI
· Integration into Synco
· Integration into Desigo via group addressing (ETS) or via individual
addressing
· Integration into third-party system via group addressing (ETS)
· AC 230 V operating voltage
· User and parameter settings can be retained or restored with power loss

Other manuals for Siemens RDF600KN

Question and Answer IconNeed help?

Do you have a question about the Siemens RDF600KN and is the answer not in the manual?

Siemens RDF600KN Specifications

General IconGeneral
BrandSiemens
ModelRDF600KN
CategoryThermostat
LanguageEnglish

Summary

Thermostat Functional Features

System Application Types

Engineering and Installation Guidance

Mounting and Wiring Instructions

Provides instructions for physical installation and wiring considerations.

Commissioning and Configuration

DIP Switch and HMI Commissioning

Using DIP switches and HMI to select thermostat applications.

Parameter Configuration and Control

System Control and Sensor Settings

Adjusting control sequence, compressor parameters, and sensor calibration.

Setpoint and Range Adjustments

Reviewing and setting temperature setpoints and limitations.

KNX Network Setup

Assigning KNX device/group addresses and configuring switching groups.

Technical Specifications

Power Supply Details

Details voltage, frequency, power consumption, and protection requirements.

Output Specifications

Specifies ratings for fan and valve control outputs.

Input Specifications

Describes multifunctional inputs, temperature sensors, and digital input functions.

Operational Data and Parameters

Operational parameters like switching differential, setpoints, and input defaults.

Terminal Connections

Wiring Connection Diagrams

Related product manuals