Technical Specifications
5.2Failsafe Alarm Relay Specifications
5.2 Failsafe Alarm Relay Specifications
Hazardous Environments
Maximum Switching Voltage Rated
Switching
Current
Isolation
30 VDC 1 A
80 VDC
30 VAC
0.3 A
1500 V
rms
for 1 minute
30 VDC 2 A 5.0 kVAC
a
between coil and contacts
1.0 kVAC
a
between contacts
250 VAC 2 A 5.0 kVAC
a
between coil and contacts
1.0 kVAC
a
between contacts
a
50 to 60 Hz for 1 minute
Non-Hazardous Environment
Maximum Switching Voltage Rated
Switching
Current
Isolation
30 VDC 2 A 5.0 kVAC
a
between coil and contacts
1.0 kVAC
a
between contacts
250 VAC 2 A 5.0 kVAC
a
between coil and contacts
1.0 kVAC
a
between contacts
a
50 to 60 Hz for 1 minute
5.3 Supported Networking Standards
The following networking standards are supported by RUGGEDCOM RSG907R:
Standard 10 Mbps
Ports
100 Mbps
Ports
1000 Mbps Ports Notes
IEEE 802.3x Full Duplex Operation
IEEE 802.3z 1000Base-LX
IEEE 802.3ab 1000Base-Tx
IEEE 802.1D MAC Bridges
IEEE 802.1Q VLAN (Virtual LAN)
IEEE
802.1Q-2005
Multiple Spanning
Tree Protocol (MSTP)
IEEE 802.1w Rapid Spanning
Tree Protocol (RSTP)
IEEE 802.1p Priority Levels
IEEE 802.1x Port-based network
access control
30
RUGGEDCOM RSG907R
Installation Manual, 10/2020, C79000-G8976-1387-10