Chapter 4
Modules
RUGGEDCOM RX1512
Installation Guide
26 Installing/Removing Line Modules
Networking: Realtek RTL8111,
RJ45 Gigabit Ethernet Interface
USB: 2 x USB 2.1
a
Video: Intel 4108 Graphics
Processor, DVI-D
a
Maximum combined USB device power consumption is 500 mA at 5 V.
Blank Modules
RUGGEDCOM RX1500PN PS XXP Specifications
Article Numbers
6GK6015-0AL10-0AA0
(Standard)
6GK6015-0AL10-0AA1
(Conformal Coated)
RUGGEDCOM RX1500PN LM Blank Specifications
Article Numbers
6GK6015-0AL20-0AA0
(Standard)
6GK6015-0AL20-0AA1
(Conformal Coated)
Section4.2
Installing/Removing Line Modules
Upon installing a new line module in the device, all features associated with the module are available in
RUGGEDCOM ROX II. For more information, refer to the RUGGEDCOM ROX II User Guide for the RUGGEDCOM
RX1512.
Once a line module is removed, all the features associated with the module are hidden or disabled in RUGGEDCOM
ROX II.
CAUTION!
Electrical hazard – risk of power failure. Do not install more than one RUGGEDCOMAPE module.
Installing more than two of this type of module can lead to power fluctuations and irregular shut
downs.
IMPORTANT!
Only one WAN line module is supported per chassis.
CAUTION!
Contamination hazard – risk of equipment damage. Prevent the ingress of water, dirts and other debris
that may lead to premature equipment failure. Always make sure slots are not left empty and open
ports are protected with plugs or covers.