Chapter 5
Technical Specifications
RUGGEDCOM RX1512
Installation Guide
30 Operating Environment
Section5.3
Operating Environment
The RUGGEDCOM RX1512 is rated to operate under the following environmental conditions.
IMPORTANT!
Temperature limits for select line modules may differ from that which can be withstood by the
RUGGEDCOM RX1512. Make sure the selected modules are rated for the expected environmental
conditions before deployment. For more information, refer to the RUGGEDCOM RX1512 Series Modules
Catalog.
Ambient Operating Temperature
b
c
d
-40 to 85 °C (-40 to 185 °F)
Ambient Storage Temperature -40 to 85 °C (-40 to 185 °F)
Ambient Relative Humidity
e
5% to 95%
Maximum Altitude 2000 m (6562 ft)
b
Maximum ambient operating temperature is 70 °C (158 °F) when the device is installed along with Underwriter Laboratories (UL) listed devices.
c
Measured from a 30 cm (12 in) radius surrounding the center of the enclosure.
d
Operating temperature may vary based on the limitations of installed SFPs. Refer to the RUGGEDCOM SFP Transceivers Catalog for SFP temperature ratings.
e
Non-condensing.
Section5.4
Mechanical Specifications
Weight Approximately 2.3 kg (5 lb)
Ingress Protection IP30
Enclosure Aluminum
Section5.5
Dimension Drawings
NOTE
All dimensions are in millimeters, unless otherwise stated.