EasyManua.ls Logo

Siemens RUGGEDCOM RX1512 - Chapter 5 Technical Specifications; Power Supply Specifications; Failsafe Relay Specifications

Siemens RUGGEDCOM RX1512
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RUGGEDCOM RX1512
Installation Guide
Chapter 5
Technical Specifications
Power Supply Specifications 29
Technical Specifications
This section provides important technical specifications related to the device.
CONTENTS
Section5.1, “Power Supply Specifications”
Section5.2, “Failsafe Relay Specifications”
Section5.3, “Operating Environment”
Section5.4, “Mechanical Specifications”
Section5.5, “Dimension Drawings”
Section5.1
Power Supply Specifications
NOTE
When determining cable lengths, make sure the minimum input voltage for the power supply is
provided at the power source.
Input Range
Power Supply Type
Min Max
Internal Fuse Rating
Maximum Power
Consumption
a
Internal 11 VDC 72 VDC 6.3 A 26.4 W
a
Power consumption varies based on the device configuration.
Section5.2
Failsafe Relay Specifications
Maximum Switching Voltage Rated Switching Current Isolation
30 VDC 2 A, 60 W
125 VDC 0.24 A, 30 W
125 VAC 0.5 A, 62.5 W
220 VDC 0.24 A, 60 W
250 VAC 0.25 A, 62.5 W
1500 V
rms
for 1 minute
between coil and contacts