Troubleshooting/FAQs
7.5 SCALANCE S device is compromised
SCALANCE S
46 Commissioning and Hardware Installation Manual, 05/2016, C79000-G8976-C266-06
Security Configuration Tool - follow the steps below:
1. If necessary, change the project to advanced mode with the menu command "View" >
"Advanced mode".
2. In the navigation area, select the VPN group you want to edit.
3. Select the "Edit" > "Properties..." menu command.
4. Generate a new key by clicking the "New..." button in the "Pre-shared key" area.
5. Confirm the next dialog with "Yes".
6. Download the configuration to all SCALANCE S modules that belong to the VPN group.
Password of a user is known
If the password of a user with administrator rights relating to configuration and/or to a module
or several modules is known, the server certificate of the corresponding module and the
password of the user should be changed.
If the password of a user who is assigned the "standard", "diagnostics" or "remote access"
role is known, the password of the user should be changed.