EasyManua.ls Logo

Siemens SCALANCE X-400 - Page 33

Siemens SCALANCE X-400
42 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Certification
5.1 Approvals, Certificates
SCALANCE X-400 extender modules
Compact Operating Instructions, 04/2013, A5E00367421-10
33
Explosion protection directive (ATEX)
The SIMATIC NET product meets the requirements of the EC directive:
94/9/EC "Equipment and Protective Devices for Use in Potentially Explosive Atmospheres"
Note
When using (installing) SIMATIC NET products in hazardous area zone 2, make absolutely
sure that the associated conditions are adhered to.
You will find these conditions on the SIMATIC NET Manual Collection.
"Approval of SIMATIC/ SIMATIC NET Products for Direct Installation in Ex-Zone 2"
ATEX classification II 3 G Ex nA IIC T4 Gc
KEMA 07ATEX0145 X
The product meets the requirements of the standards
EN 60079-0: 2009
EN 60079-15: 2005 (electrical apparatus for potentially explosive atmospheres; Type of
protection "n")
ATEX classification II 3 (2) G Ex nA [op is] IIC T4 Gc
DEKRA 11ATEX0060 X
The product meets the requirements of the standards:
EN 60079-0: 2009
EN 60079-15: 2005
EN 60079-28: 2007
FM Approval
The product meets the requirements of the standards
Factory Mutual Approval Standard Class Number 3611
FM Hazardous (Classified) Location Electrical Equipment:
Non Incendive / Class I / Division 2 / Groups A,B,C,D / T4 A and
Non Incendive / Class I / Zone 2 / Group IIC / T4
Note for Australia
The product meets the requirements of the AS/NZS 2064 standard (Class A).

Other manuals for Siemens SCALANCE X-400