EasyManua.ls Logo

Siemens SCALANCE X320-3LD FE - Construction, Installation and Environmental Conditions

Siemens SCALANCE X320-3LD FE
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7.1 Construction, installation and environmental conditions
Table 7-1 Construction
Device variant Dimensions (W x H x D) Weight Degree of protection
X304-2FE,
X306-1LD FE
60 × 125 × 123 mm 700 g IP30
X307-3,
X307-3LD,
X308-2,
X308-2LD,
X308-2LH,
X308-2LH+,
X310,
X310FE,
120 × 125 × 123 mm 1400 g IP30
X320-1FE,
X320-3LD FE
180 × 125 × 123 mm 1650 g IP30
Table 7-2 Installation options
Device variant Installation options
X304-2FE,
X306-1LD FE
DIN rail
S7-300 standard rail
Wall
X307-3,
X307-3LD,
X308-2,
X308-2LD,
X308-2LH,
X308-2LH+,
X310,
X310FE,
X320-1FE,
X320-3LD FE
DIN rail
1)
S7-300 standard rail
Wall
1)
Note: When used in shipbuilding, installation on a 35 mm DIN rail is not permitted. In ships, the 35 mm
DIN rail does not provide adequate support.
Technical data
7.1 Construction, installation and environmental conditions
SCALANCE X-300
60 Compact Operating Instructions, 11/2019, A5E00982643-18

Related product manuals