Approvals   
 
  CP 1542SP-1, CP 1542SP-1 IRC, CP 1543SP-1 
112  Operating Instructions, 01/2017, C79000-G8976-C426-03 
DE-76181 Karlsruhe 
Germany 
You will find the EC Declaration of Conformity on the Internet at the following address: 
Link: (https://support.industry.siemens.com/cs/ww/en/ps/) 
> Entry type: "Certificates", certificate type: "EC declaration of conformity" 
The CP meet the requirements of explosion protection according to IECEx. 
IECEx certificate: IECEx DEK 14.0025X 
The CP meets the requirements of the following standards: 
●  IEC 60079-0 
Hazardous areas - Part 0: Equipment - General requirements 
●  EN 60079-15 
Explosive atmospheres - Part 15: Equipment protection by type of protection 'n' 
You can see the current versions of the standards in the IECEx certificate that you will find 
on the Internet at the following address: 
Link: (https://support.industry.siemens.com/cs/ww/en/ps/) 
The conditions must be met for the safe deployment of the CP according to the section 
Notes on use in hazardous areas according to ATEX / IECEx (Page 31). 
You should also note the information in the document "Use of subassemblies/modules in a 
Zone 2 Hazardous Area" that you will find on the Internet at the following address: 
Link: (https://support.industry.siemens.com/cs/ww/en/view/78381013) 
The CP meets the requirements of the EC directive 2014/34/EU "Equipment and Protective 
Devices for Use in Potentially Explosive Atmospheres". 
Applied standards: 
●  EN 60079-0 
Hazardous areas - Part 0: Equipment - General requirements 
●  EN 60079-15 
Explosive atmospheres - Part 15: Equipment protection by type of protection 'n' 
The current versions of the standards can be seen in the EC Declaration of Conformity, see 
above. 
ATEX approval: II 3 G Ex nA IIC T4 Gc 
Test number: KEMA 07ATEX0145 X 
The conditions must be met for the safe deployment of the CP according to the section 
Notes on use in hazardous areas according to ATEX / IECEx (Page 31).