Configuring with Web Based Management
4.4 "System" menu
SCALANCE SC-600 Web Based Management (WBM)
120 Configuration Manual, 10/2021, C79000-G8976-C475-03
SSH key exchange algorithm level
Configure the level of SSH key exchange algorithm for SSH access to the CLI.
High (default)
Curve25519-sha256
Curve25519-sha256@libssh.org
Ecdh-sha2-nistp256
Ecdh-sha2-nistp384
Ecdh-sha2-nistp521
Diffie-hellman-group16-sha512
Diffie-hellman-group18-sha512
Low
Curve25519-sha256
Curve25519-sha256@libssh.org
Ecdh-sha2-nistp256
Ecdh-sha2-nistp384
Ecdh-sha2-nistp521
Diffie-hellman-group16-sha512
Diffie-hellman-group18-sha512
Diffie-hellman-group14-sha256
Diffie-hellman-group14-sha1
HTTP Server
Enable or disable HTTP access to the WBM.
HTTP Port
Specify the port for HTTP access to the WBM.
HTTPS Server
Enable or disable HTTP access to the WBM.
HTTPS Port
Specify the port for HTTPS access to the WBM.
HTTP Services
Specify how the WBM is accessed:
HTTPS
Access to the WBM is only possible with HTTPS.
Redirect HTTP to HTTPS
Access via HTTP is automatically diverted to HTTPS.