Configuring with Web Based Management
4.4 "System" menu
SCALANCE SC-600 Web Based Management (WBM)
152 Configuration Manual, 10/2021, C79000-G8976-C475-03
Description
The table has the following columns:
Client Type
Select the client type for which you want to make settings:
Log Table
Entry of system events in the log table.
Syslog
Entry of system events in the Syslog file.
Severity
Select the required Severity. The following settings are possible:
Info
The messages of all Severity are sent or logged.
Warning
The message of this Severity and the "Critical" level are sent or logged.
Critical
Only the messages of this Severity are sent or logged.
4.4.7 SMTP client
4.4.7.1 General
Network monitoring with e-mails
If events occur, the device can automatically send an e-mail, e.g. to the service
technician. The e-mail contains the identification of the sending device, a description of
the cause in plain text, and a time stamp. This allows centralized network monitoring to
be set up for networks with few nodes based on an e-mail system.