Configuring with Web Based Management
4.4 "System" menu
SCALANCE SC-600 Web Based Management (WBM)
Configuration Manual, 10/2021, C79000-G8976-C475-03
175
4.4.9.6 Notifications
SNMP traps and SNMPv3 notifications
If an alarm event occurs, a device can send SNMP notifications (traps and inform
notifications) to up to ten different management stations at the same time. Notifications
are only sent for events that were specified in the "Events" menu.
Description
The page contains the following boxes:
• SNMPv1 Traps
Enable or disable sending of SNMPv1 traps. This setting affects all receivers of
SNMPv1 traps and has no effects on receivers of SNMPv2c or SNMPv3 notifications.
• SNMPv1/v2c Trap Community String
Enter the community string for sending SNMPv1/v2c notifications.
• SNMPv3 Notify User
Select the user to which SNMPv3 notifications are to be sent.
• SNMPv3 Notify Security Level
Select the security level (authentication, encryption) to be used for SNMPv3
notification. The following options are possible:
– no Auth/no Priv
No authentication enabled / no encryption enabled.
– Auth/no Priv
Authentication enabled / no encryption enabled.
– Auth/Priv
Authentication enabled / encryption enabled.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE SC642-2C and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE SC642-2C Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE SC642-2C
CategorySwitch
LanguageEnglish

Related product manuals