Configuring with Web Based Management
4.4 "System" menu
SCALANCE SC-600 Web Based Management (WBM)
176 Configuration Manual, 10/2021, C79000-G8976-C475-03
Notification Receiver Type
The receiver type defines the SNMP version and the type of notification. SNMP
inform notifications must be acknowledged by the receiver, SNMP traps do not. The
following options are possible:
SNMPv1 Trap
SNMPv2c Trap
SNMPv2c Inform
SNMPv3 Trap
SNMPv3 Inform
Notification Receiver Address
Enter the IP address of the receiver station to which the device sends SNMP
notifications. You can specify up to ten different receivers servers.
The table has the following columns:
Select
Select the row you want to delete.
Notification Receiver Address
If necessary, change the IP address of the stations.
Notification Receiver Type
Shows the defined receiver type.
SNMP Engine ID
The ID of the SNMP engine to which SNMPv3 inform notifications are sent. You can
only configure this parameter for the "SNMPv3-Inform" receiver type.
Notification
Enable or disable the sending of SNMP notifications. Stations that are entered but
not selected do not receive any SNMP notifications.
Note
If a table row is grayed out, the corresponding notification was configured via the CLI
and can only be deleted via the CLI.