Configuring with Web Based Management
5.7 "Layer 2" menu
SCALANCE W760/W720 to IEEE 802.11n Web Based Management
Configuration Manual, 11/2014, C79000-G8976-C350-03
215
Description
The table has the following columns:
Port
Shows the available ports.
Setting
Specify whether the port should block or forward outgoing DCP frames. You have the
following options available:
Block
No outgoing DCP frames are forwarded via this port. It is nevertheless still possible to
receive via this port.
Forward
The DCP frames are forwarded via this port.
Procedure
1. Specify whether the port blocks or forwards the DCP frames.
2. Click the "Set Values" button.
5.7.5
LLDP
Link Layer Discovery Protocol (LLDP)
PROFINET uses the LLDP protocol for topology diagnostics.
In the factory settings, LLDP is activated on the interface, in other words LLDP frames are
sent and received. LLDP is supported only by the Ethernet interface.
On this WBM page, you enable or disable the sending or receiving of LLDP frames on the
interface.