SIMATIC
S7-300
S7-300 Module data
Manual
06/2017
A5E00105505
-AJ
Preface
General technical data
1
Power supply modules
2
Digital modules
3
Principles of analog value
processing
4
Principles of analog modules
5
Analog modules
6
Other signal modules
7
Interface modules
8
Parameter sets of signal
modules
A
Diagnostics data of signal
modules
B
Dimensional drawings
C
Spare parts and accessories
for S7-300 modules
D
Directive on handling
Electrostatic-Sensitive
Devices (ESD)
E
Service & support
F
Safety-relevant symbols
G
List of abbreviations
H

Table of Contents

Other manuals for Siemens SIMATIC

Questions and Answers

  • A
    Aaron BrownAug 16, 2025
    What causes EPROM fault in Siemens Control Unit and how to fix it?
    • D
      Douglas JonesAug 16, 2025
      If your Siemens Control Unit experiences an EPROM fault, this may be due to infrequent high electromagnetic interference or a defective module. Try eliminating the interference and cycling the power supply of the CPU off and on. If the problem continues, replace the module.
  • E
    Emily WilliamsAug 19, 2025
    What to do if Siemens SIMATIC shows RAM fault?
    • J
      Jessica JohnsonSep 12, 2025
      If your Siemens Control Unit experiences a RAM fault, it could be due to infrequent high electromagnetic interference or a defective module. To resolve this, first, eliminate the interference and cycle the power supply of the CPU off and on. If the issue persists, replace the module.
  • N
    nbaileyAug 22, 2025
    Why does my Siemens Control Unit show watchdog timeout?
    • A
      Allen FullerAug 22, 2025
      A watchdog timeout in your Siemens Control Unit can be caused by infrequent high electromagnetic interference or a defective module. To address this, first, eliminate the interference. If the issue continues, replace the module.
  • J
    John BurnsAug 25, 2025
    What to do if fuse is blown in Siemens Control Unit?
    • R
      Riley NguyenAug 26, 2025
      If the fuse is blown in your Siemens Control Unit module, you should replace the module.
  • E
    Erica DavisAug 27, 2025
    How to troubleshoot sensor supply missing in Siemens Control Unit?
    • J
      James BarnesAug 27, 2025
      If your Siemens Control Unit displays 'Sensor supply missing', it could be due to an overload or a short-circuit at the sensor supply. First, try to eliminate any overload. If the issue persists, eliminate any short-circuit to M at the sensor supply.
  • S
    Samuel KentAug 30, 2025
    What to do if external auxiliary voltage is missing in Siemens Control Unit?
    • C
      cristian18Aug 30, 2025
      If your Siemens Control Unit indicates that the external auxiliary voltage is missing, it is likely due to a missing power supply L+ to the module. To fix this, feed supply L+.
  • D
    Drew HensonSep 2, 2025
    Why is internal auxiliary voltage missing in my Siemens SIMATIC Control Unit?
    • D
      David GardnerSep 3, 2025
      If your Siemens Control Unit shows that the internal auxiliary voltage is missing, this could be because the power supply L+ to the module is missing or a fuse is blown in the module. To resolve this, first feed supply L+. If the issue remains, replace the module.
  • M
    Manuel GreenSep 6, 2025
    What to do if Siemens SIMATIC module is not programmed?
    • D
      Daniel MartinezSep 6, 2025
      If your Siemens Control Unit module is not programmed, it is likely due to a startup error. Program the module to resolve this issue.
  • K
    Katherine RobertsSep 9, 2025
    What causes incorrect module parameters in Siemens SIMATIC Control Unit?
    • Y
      yrodriguezSep 9, 2025
      If your Siemens Control Unit displays 'Incorrect module parameters', it means there is an implausible parameter or combination thereof. You should program the module to correct this.
  • K
    Kristen JonesSep 12, 2025
    Why is hardware interrupt lost in Siemens Control Unit?
    • C
      Colleen McknightSep 12, 2025
      If your Siemens Control Unit experiences a lost hardware interrupt, it is likely because the module cannot output an interrupt because the previous interrupt was not acknowledged, possibly due to a configuration error. To resolve this, change interrupt processing in the CPU and reprogram the module as required. The error will persist until the module is assigned new parameters.

Summary

Preface

General technical data

Provides an overview of general technical data for the S7-300 automation system, including standards, EMC, shipping and storage, mechanical and climatic conditions, and specifications.

Power supply modules

Details on power supply modules for the S7-300 PLC, covering characteristics, wiring diagrams, block diagrams, line protection, and reaction to atypical operating conditions.

Digital modules

Describes digital modules, including module overview, digital input modules, digital output modules, relay output modules, digital IO modules, selection and commissioning steps, programming, and diagnostics.

Principles of analog value processing

Explains the basic procedure for wiring and connecting signal sensors to analog inputs and outputs, including observations and general information on sensor wiring.

Principles of analog modules

Covers analog values for measuring or output ranges, analog value conversion, representation of values for analog input/output channels, and operational limits.

Dimensional drawings

Provides dimensional drawings of S7-300 components including mounting rails, power supply modules, interface modules, signal modules, and accessories.

Spare parts and accessories for S7-300 modules

Lists S7-300 parts and accessories that can be ordered separately, including order numbers for bus connectors, front connectors, and cables.

Directive on handling Electrostatic-Sensitive Devices (ESD)

Explains the meaning of electrostatic-sensitive devices (ESD) and the precautions necessary when handling modules sensitive to electrostatic discharge.

Service & support

Information on obtaining technical support, service, and training from Siemens for Industry Automation products.

Safety-relevant symbols

Explains safety-related symbols for devices without and with Ex protection, including their meaning and installation notes.

List of abbreviations

Provides a comprehensive list of abbreviations used in the document and their corresponding explanations.

Siemens SIMATIC Specifications

General IconGeneral
Product type designationSIMATIC
CPUVaries by model
MemoryVaries by model
Input/OutputVaries by model
CommunicationVaries by model
Programming LanguageSTEP 7
Operating Temperature0°C to 60°C (varies by model)
Protection ClassIP20
CategoryProgrammable Logic Controller (PLC)

Videos

How to Download Code to a Siemens S7-300 PLC in Simatic

Related product manuals