Product Overview

1.2 Functional Features of the Module

Details the module's counters, outputs, and operational capabilities, including 24-bit and 16-bit counter modes.

1.3 Quadrature Modes of Counting

Explains the 1X, 2X, and 4X quadrature counting modes for 24-bit counters, detailing input relationships and count direction.

Installing the Module

2.3 Wiring the Module

Details the I/O connections, wiring for user power, and backup power, including terminal block layout.

2.5 Configuring I/O Addresses in the Controller

Explains how to assign the I/O starting address in the PLC memory to enable controller-to-module communication.

Understanding Module Operation

3.4 Configuring Program Mode Setup Words

Details the use of WY19 and WY20 setup words for configuring counter options and modes in Program Mode.

3.5 Configuring Run Mode Setup Words

Explains the use of WY19 and WY20 setup words for configuring counter options and modes in Run Mode.

3.6 Setting Preset Values and Programming Options for Channel 1

Guides on setting preset values and programming options for Channel 1's 24-bit and 16-bit counters.

3.7 Setting Preset Values and Programming Options for Channel 2

Guides on setting preset values and programming options for Channel 2's 24-bit and 16-bit counters.

Using the Default Configurations

4.3 Basic Programming Steps

Provides a step-by-step guide to programming the module, including writing presets, programming the module, and setting RUN mode.

Optional Configurations

5.7 24-Bit Counter Software Setup Options

Guides on selecting software bits in preset and setup words to enable functions and configure 24-bit counters.

5.9 16-Bit Counter Software Setup Options

Details selecting setup word bits and preset words to enable functions and modes for 16-bit counters.

5.10 Basic Programming Steps

Outlines the steps for programming the module, including writing presets and setting the program bit to enter Run Mode.

Troubleshooting

B.2 Troubleshooting

Offers basic troubleshooting suggestions for common module symptoms like no LEDs, incorrect counts, or communication issues.