Programming via OPC UA
10.2 OPC UA variables
SIMATIC RF185C, RF186C, RF188C, RF186CI, RF188CI
132 Operating Instructions, 04/2020, C79000-G8976-C512-03
Diagnostics - Log
These variables supply various log information of the communication module.
Table 10- 22 LastLogEntry
Path
Root/Objects/DeviceSet/Read_point_x/RuntimeParameters/Diag
nosis/Logbook/LastLogEntry
Data type
String
Access
R
Description
Log diagnostics
The last entry in the log is output.
The prerequisite is that the "Parallel" or "Diagnostics" option is
set in the WBM.
Possible values
Example:
2018-05-30T13:14:43.546+00:00 | COMMANDS | readTagIDs |
CMD | 0 | Readpoint_11 | 000000005575B67D | PC=0000 |
RSSI=0 | Pwr=0
Table 10- 23 LogColumns
Path
Root/Objects/DeviceSet/Read_point_x/RuntimeParameters/Diag
nosis/Logbook/LogColumns
Data type
String
Access
R
Description
Log diagnostics
The headers column of the communication modules log is output
as formatted string. The individual fields are separated by semi-
colons.
The prerequisite is that the "Parallel" or "Diagnostics" option is
set in the WBM.
Possible values
Date_Time ; Type ; Entry ; Command_Type; Sequence_Number ;
Readpoint ; EPCID_UID ; PC ; RSSI ; Power