Configuring
6.2 Configuration via PROFINET IO
SIMATIC RF185C, RF186C, RF188C, RF186CI, RF188CI
Operating Instructions, 04/2020, C79000-G8976-C512-03
55
"Module parameters" parameter group
In this parameter group, you can configure all module-specific parameters of the
communication module.
Table 6- 3 Parameters in the "Module parameters" parameter group
Parameter
Parameter value
Default value
Description
Diagnostic interrupt Off
On
On Switching diagnostic interrupt messages of the
communication module on and off.
Parameter group "Module parameters > General parameters" of the submodules (connected readers)
In this parameter group, you can configure all module-specific parameters of the connected
readers. Please note that some of the following parameters are module-specific. For some
module types, not all parameters are displayed.
Depending on the Ident device that is connected to the respective interface (X21-X24), you
must use the matching submodule.
If no device is connected to interface X21, you need to assign an "Empty" module to this
interface.
Table 6- 4 Parameters of the parameter group "Module parameters > General parameters" of the submodules (connect-
ed readers)
Parameter
Parameter value
Default value
Description
User mode Ident profile/RFID stand-
ard profile
FB 45
Ident profile/RFID
standard profile
With this parameter, you select the block:
Ident profile/RFID standard profile:
Single tag / multitag mode. The program
block for the Ident profile is used in the con-
troller.
FB 45:
Single tag mode. FB 45 is used in the con-
troller
MOBY mode RF200/RF300/RF600;
MV400/MV500; MOBY
U/D normal addr.
RF200/RF300/RF60
0; MV400/MV500;
MOBY U/D normal
addr.
With this parameter, you set the mode of the
communication module.
RF200/RF300/RF600; MV400/500; MOBY
U/D normal addr.
Normal addressing: The transponder is ad-
dressed with physical addresses.
Transmission
speed
19.2 kBd
57.6 kBd
115.2 kBd
921.6 kBd
115.2 kBd With this parameter, you set the data transmis-
sion speed between the communication module
and the reader.
When an optical reader is connected: The
transmission speed selected here must match
the transmission speed selected for the reader.