EasyManua.ls Logo

Siemens SIMATIC RF186C - Page 85

Siemens SIMATIC RF186C
208 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuring with the WBM
7.3 The menu items of the WBM
SIMATIC RF185C, RF186C, RF188C, RF186CI, RF188CI
Operating Instructions, 04/2020, C79000-G8976-C512-03
85
The "XML" tab
The "XML" tab is divided into the following areas:
Basic settings
XML channel
Figure 7-10 The "Settings - Communication" menu item, "XML" tab
Basic settings
You can the XML communication of the communication module in the "Basic settings" area.
Click on the check box to enable or disable it.
Table 7- 13 Description of the parameters
Parameter
Description
Parallel In addition to an existing connection, e.g. to a controller (PLC), parallel diag-
nostics access via the XML channel is enabled. In the case of parallel access,
note that the XML application only has read access to the communication
module.
Reliable transfer If the check box is selected, each frame (XML report) received from the user
application of the communication module is confirmed with a response frame.
If no response frame is received by the communication module within 10 sec-
onds, it sends the report to the application again. Reports that are not trans-
ferred are buffered on the communication module.
With this function, you can make sure that no frames from the communication
module are lost even if the connection is unstable (e.g. WLAN connection
aborts occasionally). This function also allows batch operation of the commu-
nication module when there is a connection to the user application at certain
times. The communication module collects the frames; these can be called up
using a PC application, if necessary.
XML channel (1-4) Specifies which XML channels are used for communication.
Below the check boxes, you can define the Ethernet ports of the respective
XML channels in the text boxes.

Table of Contents

Related product manuals