CPU 1515R-2 PN (6ES7515-2RN03-0AB0)
Equipment Manual, 11/2022, A5E42009914-AD
10
Product overview
3
3.1 New functions
This section contains an overview of the most important new firmware functions of the CPU
compared with the predecessor version CPU (V2.9).
New functions of the CPU in firmware version V3.0
New functions Customer benefits Where can I find information?
Integrated work memory for program and data
expanded
The expansion of the integrated work
memory allows you to implement larger
and more extensive applications with the
CPUs.
Section Technical specifications
Data block functions As of FW version V3.0, the instructions for
the data block functions are supported:
• CREATE_DB (create data block)
• READ_DBL (read from data block in the
load memory)
• WRIT_DBL (write to data block in the
load memory)
• DELETE_DB (delete data block)
STEP 7 online help
Network Management Protocol SNMP:
A simple configuration option is available for
use of SNMP services. For new configurations,
this is disabled by default in accordance with
"Security-by-Default".
Can be enabled/disabled in the CPU prop
erties. Community strings can be con
figured.
Communication Function Manual
(https://support.industry.siemens.
com/cs/ww/en/view/59192925)
Trace: The S7-1500 CPU supports up to 64 con
figured signals per trace.
Number of configurable signals per trace
extended
Using the Trace and Logic Analyz
er Function Function Manual
(http://support.automation.
siemens.
com/WW/view/en/64897128)
New functions of the CPU in firmware version V2.9
New functions Customer benefits Where can I find information?
Influence switchover time
of switched S1 devices
As of FW version V2.9, you can influence the
switchover time between disconnection and return of
switched S1 devices after a failure/STOP of the primary
CPU.
This function offers the following advantages:
• Optimization of the switchover time between dis
connection and return of switched S1 devices
PROFINET Function Manual
(http://support.automation.siemens.
com/WW/view/en/49948856)