Function Description Additional information
PROFINETIO
System redundancy S2 IO-Devices with S2 system redundancy enable uninter
rupted operation during a primary backup switchover.
If the role of the CPUs changes, the new primary CPU
takes over the PROFINETIO communication.
S7-1500R/H redundant system
(https://support.industry.siemens.
com/cs/ww/en/view/109754833)
system manual
Function manual PROFINET
(http://support.automation.
siemens.
com/WW/view/en/49948856)
Switched S1 device The switched S1 device function of the CPU enables
operation of standard IO devices in the S7‑1500R/H
redundant system.
S7-1500R/H redundant system
(https://support.industry.siemens.
com/cs/ww/en/view/109754833) sys
tem manual
RT (real time) RT prioritizes PROFINETIO frames over standard frames.
This ensures the required determinism in the automation
technology. In this process the data is transferred via pri
oritized Ethernet frames.
MRP (Media Redundancy
Protocol)
The Media Redundancy Protocol enables the configura
tion of redundant networks. Redundant transmission
links (ring topology) ensure that an alternative commu
nication path is made available if a transmission link fails.
Within the PROFINET ring, the R-CPUs assume the role of
the MRP Manager following appropriate project configur
ation and all other devices in the ring assume the role of
the MRP clients.
MRP interconnection The process MRP interconnection is an enhancement of
MRP and allows redundant coupling of two or more rings
with MRP in PROFINET networks. MRP interconnection is -
like MRP - specified in the standard IEC 62439-2 (Edition
3).
PROFIenergy PROFIenergy is a PROFINET-based data interface for
switching off consumers centrally and with full coordina
tion during pause times regardless of the manufacturer
or device type. Through this, the process should only be
provided with the energy that is absolutely required.
Most of the energy is saved by the process. The
PROFINET device itself only contributes a few watts to
the savings potential.
Function manual PROFINET
(http://support.automation.siemens.
com/WW/view/en/49948856)
Integrated technology
Integrated closed-loop con
trol functionality
PID Compact (continuous PID controller)
PID 3Step (step controller for integrating actuators)
PID Temp (temperature controller for heating and
cooling with two separate actuators)
Function manual PID Control
(https://support.industry.siemens.
com/cs/ww/en/view/108210036)
Controlling, measuring and
position detection
TO_BasicPos (control of a SINAMICS drive)
SSI_Absolute_Encoder (control of position detection
and measuring function of the TMPosInput techno
logy module)
STEP7 online help
Security Integrated
18
CPU 1515R-2 PN (6ES7515-2RN03-0AB0)
Equipment Manual, 11/2022, A5E42009914-AD
Product overview
3.4 Firmware functions